Search results for "Sequential injection analysis"

showing 6 items of 6 documents

Environmentally friendly analytical chemistry through automation: comparative study of strategies for carbaryl determination with p-aminophenol

1999

Abstract A flow system, based on multicommutation and binary sampling, has been developed for improving the automated spectrophotometric determination of carbaryl with p -aminophenol (PAP) in order to reduce the waste volume and to preserve the maximum analytical performance. The procedure, which was implemented employing a flow network obtained by nesting five, three-way solenoid valves controlled by means of a 386 microcomputer equipped with an electronic interface running software written in quick basic 4.5, provides a limit of detection of 26 μg l −1 , comparable to that obtained using a conventional flow injection (FIA) manifold and lower than that found by sequential injection analysi…

Detection limitSequential injection analysisChromatographyChemistrybusiness.industryAnalytical chemistryFlow networkBiochemistryAutomationEnvironmentally friendlyAnalytical Chemistrychemistry.chemical_compoundVolume (thermodynamics)MicrocomputerCarbarylEnvironmental ChemistrybusinessSpectroscopyAnalytica Chimica Acta
researchProduct

Indirect spectrophotometric determination of p-aminobenzoic acid in sunscreen formulations by sequential injection analysis

2003

Abstract A simple indirect sequential injection spectrophotometric method for the determination of the UV-filter p -aminobenzoic acid (PABA) in sunscreen formulations is proposed. The determination is based on the reaction of PABA with hypochlorite in acidic medium and the subsequent measurement of the residual chlorine by using the well-known reaction with o -tolidine. The experimental variables involved in the sequential injection analysis (SIA) system (sandwich arrangement, volumes of sample and reagents, propulsion flow rate, reaction coil length) and adequate concentrations of reagents were studied. The SIA method has a linear range up to 20 μg ml −1 (3 s y / x / b detection limit) of …

Detection limitSequential injection analysisChromatographymedicine.diagnostic_testTolidineHypochloriteBiochemistryAnalytical Chemistrychemistry.chemical_compoundLinear rangechemistrySpectrophotometryReagentmedicineEnvironmental ChemistryAminobenzoic acidSpectroscopyAnalytica Chimica Acta
researchProduct

Recent developments in flow-analysis vibrational spectroscopy

2007

Abstract This review deals with developments in the new century on the use of vibrational spectroscopy techniques for detection in flow-injection analysis (FIA) systems. To provide a picture of the evolution, highlights and future developments in this field, we revisited Fourier transform infrared (FTIR), in the mid-IR and near-IR ranges, and FT-Raman spectrometry applications using different approaches, from classical FIA to modern (sequential injection analysis (SIA) or multicommutation). We used the analytical abstracts database for 2000–06 for the literature search, but we based this review very much on the experience of our team in this field.

Sequential injection analysisChemistryAnalytical chemistryInfrared spectroscopyFourier transform spectroscopyAnalytical Chemistrysymbols.namesakeSequential methodFourier transformFlow (mathematics)Systems engineeringsymbolsFourier transform infrared spectroscopySpectroscopyTrAC Trends in Analytical Chemistry
researchProduct

Application of sequential injection analysis to pharmaceutical analysis.

2005

Sequential injection analysis is a well established tool for automation of pharmaceutical analysis. A short historical background of this technique is given as well as a brief discussion on the basic principles and potentials. The current applications of SIA in the pharmaceutical analysis are also described and discussed. The manifolds developed offer good analytical characteristics and are suitable for analysis of drug formulations, process analysis, drug-dissolution, drug-release testing and functional assays for screening potential drugs. The results obtained are in good agreement with those furnished by the application of the reference methods presented in the pharmacopoeias.

Sequential injection analysisDrug IndustryChemistry PharmaceuticalClinical BiochemistryPharmaceutical ScienceBiological AvailabilityDrug formulationsAnalytical Chemistrylaw.inventionlawPharmacopoeias as TopicProcess analysisDrug DiscoveryElectrochemistryTechnology PharmaceuticalPharmaceutical SolutionsSpectroscopyPharmacopoeias as TopicChemistrybusiness.industryAutomationPharmaceutical SolutionsSpectrometry FluorescenceSolubilitySpectrophotometryCalibrationBiochemical engineeringPharmacopoeiabusinessBiological availabilityJournal of pharmaceutical and biomedical analysis
researchProduct

Scientometric Picture of the Evolution of the Literature of Automation in Spectroscopy and Its Current State

2006

Abstract The current study focuses on the status of automation and mechanization in spectroscopy for analytical chemistry publications compiled during the period 1980–2006, in Analytical Abstracts. Flow injection analysis (FIA), sequential injection analysis (SIA), multicommutation, and monosegmented and segmented flow strategies were considered. For assessing the evolution of scientific productivity, the total number of publications concerned with the different methodologies was evaluated. In order to provide a picture of the state of the art of this field, the most important journals, the most active authors, and the most productive countries in the field of automation were evaluated in t…

Sequential injection analysisManagement scienceChemistrybusiness.industryAnalytical Chemistry (journal)State (computer science)businessAutomationSpectroscopyAtomic and Molecular Physics and OpticsScientific productivityAnalytical ChemistrySpectroscopy Letters
researchProduct

Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals

2007

Abstract A review is presented on the state of the art of the chemiluminescence analysis of pharmaceuticals by the two most relevant automated controlled-flow methodologies—flow-injection analysis (FIA) and sequential-injection analysis (SIA). The current chemiluminometric applications of FIA and SIA in pharmaceutical analysis are discussed with special emphasis on the analytical figures of merit and sample matrix characteristics. The review involving 211 references and covering papers published between 2001 and 2006 is divided into several sections according to the fundamental types of chemiluminescence systems employed.

Sequential injection analysisbusiness.industryChemistryClinical BiochemistryAnalytical chemistryPharmaceutical ScienceAnalytical Chemistrylaw.inventionPharmaceutical PreparationslawFlow Injection AnalysisLuminescent MeasurementsDrug DiscoveryProcess engineeringbusinessOxidation-ReductionSpectroscopyChemiluminescenceJournal of Pharmaceutical and Biomedical Analysis
researchProduct